Series 930 Fixed Gas Transmitter and Controller

Robust IP65 Networkable Ozone Monitor.

SKU
S930
Only 0 left

Series 930 Fixed Gas Transmitter and Controller Overview

The Series 930 Fixed Gas Monitor is a flexible monitor compatible with a range of gas sensors as well as a temperature and humidity sensor, if required. The sensor is housed in a robust IP65/NEMA 4 rated water resistant enclosure protecting it from water damage. There is also the option to include an integrated display for reporting real-time gas concentrations and/or an optional strobe and siren kit which can be configured to activate to a user defined set point.
 
The Series 930 outputs are designed to measure and control gas concentrations and communicate to a variety of hardware systems. The monitor can operate in three ways:
  • As a relay controller via the integrated relays and user configurable set points to control an external device such as an ozone generator or initiate an alarm.
  • As a gas transmitter via the 4-20 mA output which allows connection to a PLC or current sensing device to provide gas concentration information for applications such as health and safety monitoring.
  • As a monitoring network via the RS485 digital output to enable gas monitoring at several indoor locations with information being logged to a central point.
The Series 930 monitor is easy to install due to the lightweight enclosure and provided wall mounting kit. It requires a 24V power supply which is user supplied to allow flexibility in locations it can be installed.  

For more information on the Series 930 Fixed Gas Transmitter, contact your local Air-Met office. 
 

Series 930 Fixed Gas Transmitter and Controller Features

  • Active sampling for higher accuracy
  • Tamperproof, water-resistant enclosure
  • Multiple output transmitter
  • Real-time network capability
  • PC data logging and networking
  • Large LED local display (Optional)
  • Temperature and RH sensor (Optional)

Series 930 Fixed Gas Transmitter and Controller Specifications

Measurement units Gas: ppm or mg/m3 | Optional: Humidity: % a Temperature: °C or °F
Reading functions Instant, minimum, maximum, average
Sensor head Type Sensor head removable / replaceable
Sampling method Active sampling via internal sensor head fan
Analog output 4-20 mA (opto-isolated), 12-24 Vdc
External signal type Transistor output (4) (24 Vdc at 150 mA max)
External signal functions Low Alarm | High Alarm | Control | Diagnostics
External signal input Standby toggle
Connectors Screw type
Monitor identification 1 (Default) User configurable from 1 to 255
Alarm set points User configurable Low Alarm | High Alarm
Control set point User configurable Low Alarm | High Alarm
Communication RS-485 (Aeroqual proprietary protocol)
Software Free PC configuration software and logging link data to a specific location and monitor (data cable required)
Interface (optional) RS-485 to USB cable
Power (user supplied) 24 Vdc, 500 mA (range 22-24 Vdc)
Monitor base/enclosure material and rating Polycarbonate | IP41 NEMA 2 equivalent
Size (with sensor head L x W x H) 180 x 110 x 90 mm 7 â…› x 4¾ x 3½ in
Weight (incl. sensor) < 850 g; < 30 oz
Environmental operating conditions 0°C to 40°C 32°F to 104°F
Approvals Part 15 of FCC Rules, EN 61000-6-3: 200, EN 61000-6-1: 2001

Series 930 Fixed Gas Transmitter and Controller Applications

  • Health and safety monitoring
  • Industrial process control
  • Toxic gas leak detection
  • Indoor air quality monitoring
  • Real-time network monitoring
  • Gases available: O3, VOC, H2S, NH3, SO2, NO2, CH4, or CH20

Series 930 Fixed Gas Transmitter and Controller Support

Aeroqual S930 SpecificationsAeroqual S930 User Guide