Wall Mount CO2 Fixed Gas Monitor
Designed for Carbon Dioxide (CO2) Detection in Storage Facilities within the Beverage Industry.
SKU
WALLCO2
Indoor Air Quality (IAQ) is measure of the quality of air in interiors; the comfortable indoor environmental quality can make people feel fresh, work efficiency and good for the health. The CO2 concentration is an important factor in good indoor air quality.
The CO2 Wall Mount Monitor is a cost effective and reliable unit designed to detect the presence of carbon dioxide (CO2) in the ambient air to protect people in confined spaces or simply to monitor the living and working environment. With the simple fact that more windows are often closed to avoid noise, dust or simply because people enjoy the comfort of living and working in an air conditioned office, this usually results in increased indoor concentrations of carbon dioxide when compared to the outdoor environment. High concentrations of CO2in confined spaces is dangerous and may lead to a range of health problems ranging from headaches and fatigue to asphyxiation and death.
The CO2 Wall Mount Fixed Gas Detector is not limited to applications in wineries. The unit is also a cost effective solution for carbon dioxide monitoring at swimming pools, gymnasiums, offices and more.
For more information on the Wall Mount CO2 Fixed Gas Monitor, contact your local Air-Met office.
Wall Mount CO2 Fixed Gas Monitor Features:
- Dual Beam NDIR (Non-Dispersive Infrared) technology is used to measure CO2 concentration up to 50,000 ppm (parts per million) and electrochemical technology to measure O2 concentration up to 30%.
- With the SEU (Sensor Unit) and RDU (Remote Display Unit), it can connect up to 3 RDU for safety notices.
- Large digital LCD display clearly indicates the ambient CO2, O2(optional) Concentration and Temperature.
- Relay output can automatically control a fan to ventilate confined spaces.
- Audible and Visual Alarm indications.
- IP54 Water Proof Protection of SEU (Sensor Unit) except backside when installed on the wall.
Method | Dual Beam NDIR |
Sample Method | Diffusion or flow through (50 ~200 ml/min) |
CO2 Performance | |
---|---|
Measurement Range | 0~50,000ppm (5%) display |
Display Resolution |
1ppm at 0~1,000ppm;
10ppm at 1001~10,000ppm;
100ppm at 10,001~50,000ppm
|
Accuracy | ±100ppm or ±5% of reading, whichever is greater |
Repeatability | ±20ppm @400ppm |
Annual Drift | <20 ppm/Year@400ppm |
Temperature Dependence |
±0.2% of reading per °C or ±2ppm per °C,
whichever is greater, referenced to 25°C
|
Pressure Dependence | 0.13% of reading per mm Hg |
Response Time | <60 seconds for 90% response to step change |
AL1 (First Alarm Level)
|
5000ppm, 1 / 1.5 / 2 % , Default AL1= 1.5% |
AL2 (Second Alarm Level)
|
1.5 / 2 / 2.5/ 3 / 3.5 / 4 % , Default AL2= 3% |
Warm-Up Time | <60 seconds at 22°C |
Sound Alarm | 80db@10cm |
Power and Supply | |
---|---|
Power and Supply | AC adapter 110/220 VAC |
AC Input | Voltage: 100 ~ 240 VAC Frequency: 50 / 60 Hz Power Requirement: 1 W maximum @ 115 VAC 60 Hz 2 W maximum @ 230 VAC 50 Hz |
AC/DC Output | Voltage: 6VDC Power: 3.0W |
Peak Input Current | 0.5 A from 6 VDC |
Analogue Output (ZG10Un Only) | Two channel linear current output 4~20mA for O2, RL<150Ω; 4~20mA for CO2, RL<150Ω. |
Relay Output |
Peak Current<2A@30VDC or 250VAC, SPDT for CO2/O2
|
Temperature and Operating Specifications | |
---|---|
Temperature Range:
|
0°C to 50°C ( 32°F to 122°F) |
Display Resolution: | 0.1°C (0.1°F) |
Display Options: | °C/°F) |
Accuracy: | ±1°C(±2°F) when CO2 concentration is below first alarm level |
Response Time: | 20-30 minutes (case must equalize with environment) |
Operating Conditions |
Operating Temperature: 0°C to 40°C ( 32°F to 104°F), 0-95% RH, non-condensing
Storage Temperature: -20 to 60°C ( -4 to 140°F)
|
Dimensions |
SEU: 170.0 ×126.0 × 63.0 mm (6.69 × 4.96 × 2.48 inch)
RDU: 80.0 × 110.0 × 35.7 mm (3.15 × 4.33 × 1.41 inch)
|
- Carbon dioxide monitoring
- Workplace health and safety
- Swimming pools
- Gymnasiums
- Winery/ brewery safety applications