Universal 44XR Sample Pump
Constant Flow Air Sampling Pump with a Wide Flow Range.
SKU
UNIVERSAL44XR
The Universal 44XR, 5 to 5000 ml/min, economical turn-on-and-sample personal or area sample pump provides up to 12-hour run times for sampling particulates and gases/vapours.
The pump is ideal for use with sorbent tubes, filter cassettes, size-selective samplers, sample bags, and impingers. The Universal 44XR is UL Listed for intrinsic safety.
For more information on the Universal 44XR Sample Pump, contact your local Air-Met office.
- Economical
- Basic operation
- Convenient flow indicator
- Designed for rugged industrial environments
- One-year warranty
- Ultra-quiet operation
- Pulsation-free flow
- Impact-resistant case
Operating Range
|
1000 to 5000 ml/min (UL Listed model)
1000 to 3000 ml/min (MSHA-approved model)
(5 to 500 ml/min requires the Cat. No.224-26 Series adjustable low flow holder)
Requires 1/4-inch ID tubing
|
Weight | 34 oz (964 gm) |
Dimensions | 5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm) |
Compensation Range |
1000 to 2500 ml/min at 40 inches water back pressure
3000 ml/min at 35 inches water back pressure
4000 ml/min at 20 inches water back pressure
5000 ml/min at 10 inches water back pressure
|
Flow Control | Holds constant flow to ± 5% of set-point |
Run Time |
NiCad Battery: 8 hours minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 3.
NiMH Battery: 12 hours minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 2.
Battery Eliminator: Pump provides extended runs.
|
Tubing | 1/4-inch ID tubing, required |
Flow Indicator | Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min |
Power Supply |
6.0-V plug-in NiMH battery pack, rechargeable, 3.5-Ah capacity or 6.0-V plug-in NiCAD battery pack, rechargeable, 2.0-Ah capacity
A battery eliminator is available (see Ordering Information); use voids the UL Listing for intrinsic safety.
|
Intrinsic Safety |
UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C
ATEX-approved models are available. Contact Air-Met Scientific for more information.
|
Operating Temperature | 32° to 113°F (0° to 45°C) |
Storage Temperature
|
-4° to 113°F (-20° to 45°C) |
Charging Temperature | 50° to 113°F (10° to 45°C) |
Operating Humidity | 0 to 95% non-condensing |
Multiple-tube Sampling | Built-in constant pressure regulator allows user to take up to four simultaneous samples with rates up to 500 ml/min each (total combined flow 1350 ml/min maximum) using the optional adjustable low flow holder accessory. |
RFI/EMI Shielding |
Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1
Frequency range of the radiated susceptibility test was 27 to 1000 MHz
CE marked
|
Additional Specifications |
|
- Hazardous chemical gases and vapour sampling
- Respirable dust collection
- Asbestos
- Collection of airborne chemical hazards
- Collection of reactive chemicals into liquids
- Indoor air quality monitoring
- Fenceline monitoring