Related Products
Smarts II Area Radiation Monitors
Surveillance Monitor - Fixed High Frequency Warning Device
SKU
SMARTSII
Smarts II Area Radiation Monitors Overview
Area Monitor that can be installed on ceilings and walls, with automatic frequency response evaluation according to a selected standard. Smarts II emits warning sounds and registers alarms if user settable thresholds are exceeded. Smarts II is ideal for security installations in aircraft hangars or military facilities, thanks to its frequency range from 2 MHz to 100 GHz and measurement range of up to 3000% of the limit value of the chosen standard.
For more information on the Smarts II Area Radiation Monitors, contact your local Air-Met office.
Smarts II Area Radiation Monitor Features
- 2 MHz to 100 GHz in a single monitor
- Shaped frequency response matched to your standard
- Continuous, automatic monitoring – No operator required
- Recorder output
- Battery or low voltage DC operation
- Weatherproof housing option
- Real time frequency response evaluation
- Audible and visible alarms
- Remote monitoring
- User settable alarm thresholds
Smarts II is available for the following standards:
- ACGIH
- Canada Safety Code 6, RF / Microwave Worker
- FCC 1997, Occupational / Controlled
- ICNIRP 1998, Occupational
- IEEE C95.1-1999/ANSI C95.1-1992, Controlled
- NATO STANAG 2345
Smarts II Area Radiation Monitor Specifications
Parameter | Specification |
---|---|
Model Number | A8830 through D8830a |
Frequency Range | 2 MHz to 100 GHz |
Frequency Sensitivity | +6.0/-3.0 dB (100kHz to 2.3 GHz) +4.5/-2.5 dB (2.3 to 30GHz)
+2.5/-6.0 (30 to 50 GHz)
+2.5/-6.0 (50 to 100 GHz, Typical)
|
Calibration Frequencies | 100 MHz, 4 GHz |
Alarm Threshold | 10%, 25%, 35%, or 50% of Standard |
Maximum CW Power Density | 3000% of Standard |
Maximum Peak Power Density | 32dB above Standard |
Battery | 9 volt alkaline |
External Power Requirements | 12 Vdc ± 10%, 50 ma max / 24 Vdc ± 10%, 50 ma max |
STATUS Signal Levels | -4 Vdc standby, +4Vdc alarm (nominal) |
Status Relay | SPDT |
Recorder Output Level | -1 Vdc full scale (approximate) |
Temperature | Operating: -10°C to +55°C Non Operating: -20°C to +55°C |
Size | 9.4” L x 8.1” W x 5.0” H 23.9 cm x 20.6 cm x 12.7 cm |
Weight | 26 oz / 0.74 kg |
Color | White |
Accessories Supplied | Mating 9-pin connector, Battery, Operation Manual |
Optional Accessory | Mounting Adapter Kite |
Smarts II Area Radiation Monitor Applications
- Indoor radiation area monitoring
- Outdoor radiation area monitoring