smartMODUL CO2 And Ethylene Sensors
Infrared Gas Sensors For The Detection Of Ehtylene In Fruit Ripening Processes.
In order to ensure that the fruit comes out of the transportation and storage periods in good condition, they are preserved in a protective atmosphere. The degree of ripeness and growth can be selectively influenced by means of a defined temperature and through controlled concentrations of CO2, O2 and C2H4. Reliable and accurate gas sensors are necessary for the monitoring of the correct concentrations. This is where the CO2 and C2H4 sensors come in.
Developed for ethylene detection in the fruit ripening process and food storage applications, these smartMODUL for ethylene detection help you in the accurate monitoring and efficient checking of the ripening process regardless of whether it is during storage or transportation.
The smartMODUL for Ethylene Infrared Gas Sensor has a measurement range of 0-2000 ppm (Model Type: F1-030205-00001)
For more information about integrated systems, contact Air-Met Scientific today.
- Flow operation
- Infrared measuring principle (NDIR)
- Dual beam technology
- Modbus ASCII via UART
- Robust aluminium cuvette
- 3/5mm gas line connectors
- Pre calibrated
- High selectivity
- Customer-specific modules possible
For full product specifications, please refer to the product brochure.
General Features | |
---|---|
Measurement Principle: | Non Dispersive Infra-Red (NDIR), dual wavelength |
Measurement Range: | 0-2000 ppm |
Gas Supply: | By flow |
Gas Line Connectors: | 3 mm interval, 5mm outer diameter |
Flow Rate: | 0.2 to 0.8l/m (constant) |
Dimensions: | ~ 261mm x 28mm x 42mm (L X W X H) (including optical CO2 filter) |
Warm Up Time: | < 2 minutes (start up time) < 30 minutes (full specification) |
Measuring Response1 | |
---|---|
Response time (t90) | Approx 15 seconds (@ 0.5l/m) |
Digital Resolution (@ zero): | 1 ppm |
Detection Limit: | ≤ 1% Full Scale (typically) |
Repeatability: | ≤ +/- 1% Full Scale |
Linearity Error2 | ≤ +/- 2% Full Scale |
Electrical Inputs & Outputs | |
---|---|
Supply Voltage: | |
Supply Current: | 70 mA Average, max. 140mA |
Power Consumption: | < 1 Watt |
Digital Output Signal: | Modbus ASCII via UART |
Calibration: | zero and span by jumper or SW |
Climate Conditions | |
---|---|
Operating Temperature: | -10 °C to 40 °C (others possible) |
Storage Temperature: | -20 °C to 60 °C |
Air Pressure: | 800 to 1200 hPa |
Humidity: | 0 % to 95 % rel. humidity (not condensing) |
1 Relating to atmospheric pressure 1013 hPa absolute and 25 °C ambient temperature (type Diffusion) or sample gas pressure 1013 hPa absolute, 0.5 l/min gas flow and 25°C ambient and gas temperature (type Flow)
2 Stated linearity error excludes calibration gas tolerance of +/- 2%
- Fruit ripening storage and transport facilities