Simtronics MultiTox DGI-TT7 Solid-State (MOS) Gas Detector
Designed For The Detection Of Hydrogen Sulfide In Dry Locations.
![Loading...](https://www.airmet.com.au/pub/static/version1731934622/frontend/Smartwave/porto/en_AU/images/loader-1.gif)
The MultiTox DG-TT7 Solid State Gas Detector is a reliable gas detector mainly used for the detection of hydrogen sulphide (H2S) in hot and dry environments. The device can also be configured to detect other gases, such as refrigerants (e.g. R22).
The sensing element in this robust unit only needs to be replaced once a year making this gas detector low maintenance. Additionally, the device does not need a high gas concentration to reactive the active sensing material.
The microprocessor driven unit is fully configurable using a wireless hand-held terminal (TLU) or through the use of a hard wired HART option. Elements such as relay operation and alarm levels are all
set via the TLU.
The device may also be interfaced directly with a wide range of panels, controllers and PLC’s.
For more information on the Simtronics MultiTox DGI-TT7 Solid-State (MOS) Gas Detector, contact your local Air-Met office.
Features & Benefits
- Recalibration only required once a year
- Replaceable cartridges
- Non-consumable process
- Resistant to high gas concentrations
- Integral daylight readable backlit LED display
- Hand-held maintenance terminal
- Hot swap field cabling
- HART® output option available
Simtronics MultiTox DGI-TT7 Solid-State (MOS) Gas Detector Specifications | |
---|---|
General | |
Technology | Solid-state Metal Oxide Semiconductor |
Detects | Hydrogen Sulphide |
Range |
0 - 50 ppm H2S
0 - 1 00 ppm H2S
|
Performance | |
Response Time |
T50 < 30 s
T90 < 1 20 s
|
Accuracy | +/- 4 ppm or +/- 1 5% reading |
Zero Drift | +/2 ppm |
Sensor Life | Better than 5 years |
Output Signal | |
Standard |
4-20mA, max. load impedance 700L (Std. )
2 x configurable Relays max 1 A / 30V
|
Option HART(R) | HART Protocol (7th edition) |
Option | 0-22mA (User configurable) |
Option | Lonworks (Syntel) |
Local Display |
4 digit led display and backlight color status
with automatic intensity adjustment
|
Environmental | |
Storage | -40°C to +70°C (-40°F to +1 58°F) |
Operation | -40°C to +65°C (-40°F to +1 49°F) |
Option | Sunshade, max. temp. 85°C (1 85°F) |
Humidity | 99% RH (non-condensing) |
Pressure | Atmospheric pressure +/- 1 0% |
Ingress | IP66 |
RFI/EMI | Complies with EN50270 |
Housing | |
Material | 316 L stainless steel |
Weight | 4 Kg (8Lbs) |
Approvals | |
ATEX |
II 2 G Ex d IIC T6 Gb
(-40°C to +65°C / -40°F to +149°F)
|
Certificate Number | LCIE 11 ATEX 3081X |
IECEx |
Ex d IIC T6 Gb
IECEx LCI 11.0060X
|
- Refineries
- Drilling and Production platforms
- Processing and Storage plants
- Chemical plants