Portacount Respirator Fit Tester 8038
Respirator Fit Testing You Can Trust.
No other respirator fit tester can quantitatively fit test all types of respirators-gas masks, SCBAs, respirators, even N95, P1 and P2 disposable (filtering-facepiece) respirators. The PortaCount® Pro+ Respirator Fit Tester 8038 eliminates the guesswork associated with tedious and error-prone qualitative fit test methods. If the mask requires fit testing, count on the PortaCount Pro+ Fit Tester to provide the fastest, easiest and best HSE (UK) and OSHA (US)-compliant fit test method.
For more information, please contact your local office.
- Fit test ANY tight-fitting respirator including N95, P2 and P1 disposables
- Faster N95 fit testing time -- down from 10 minutes 24 seconds to 7 minutes 15 seconds
- Greater simplicity with the built-in N95 Companion™ technology
- Standalone operation - no external computer required
- Use with external computer to generate reports and print fit test cards
- Able to perform N95 fit testing with much lower ambient particle concentrations
- Color touch screen enables operation via touch of a finger, pen or stylus
- HSE (UK) and OSHA (US) -compliant for all respirators, including N95, P1 and P2
- Measures fit factors greater than 10,000
- Switch between different respirator types in under a minute
- Automates fit testing with FitPro+™ Fit Test Software
- Interactive training tool for initial and follow-up training
TSI PortacCount Fit Tester Specifications | ||
---|---|---|
Fit Factor Range | 1 to greater than 10,000, 1 to 200 for N95 masks | |
Typical Fit Factor Accuracy | ±10% of reading | |
Respirator Facepieces that can be Fit Tested |
Full-face elastomeric
Half-face elastomeric
NIOSH series-100 filtering-facepiece
NIOSH series-99 filtering-facepiece
NIOSH series-95 filtering-facepiece
P3 filtering-facepiece
P2 filtering-facepiece
P1 filtering-facepiece
|
|
Fit Factor Measurement | Direct measurement of fit factor (Cout/Cin)* | |
Dimensions | 6.75 in. x 8.5 in. x 9.5 in. (17 cm x 22 cm x 24 cm) | |
Weight |
Unit Only: |
3.1 kg |
Power | Autosensing 100 to 250 VAC, 50 to 60 Hz | |
Flow Rate |
Sample: |
350 cm3/min |
Alcohol |
Hours Per Charge: |
6 hours at 70°F (21°C) |
Pass/Fail Setting | User-selectable: 0 to 10,000 | |
Factory Calibration Interval | one year |
- Quantitative respirator fit testing (QNFT)
- Disposable filtering-facepiece fit testing for Series 100/99/95/P1/P2/P3/ HEPA masks
- Half-mask fit testing
- Full-face fit testing
- Gas mask fit testing
- PAPR fit testing
- SCBA fit testing