LO-PRO Low Profile Air Strippers
Highly Efficient Water Treatment Systems that Remove VOCs from Water.
SKU
LOWPRO

Geotech LO-PRO™ models II and III are highly efficient water treatment systems that can remove up to 99.99% of many volatile organic compounds (VOC’s) from water.
Systems are self-contained for use in limited space applications.
Contaminated water enters the Geotech LO-PRO™ at the top of the unit and cascades onto the first of a series of stainless steel bubble plates. A baffle in the centre of each plate redirects the water 180° in each stage as it flows downward, alternating between clockwise and counter clockwise directions. This action optimises the residence time of the water in the Geotech LO-PRO™, allowing for efficient contaminant removal.
For more information on the LO-PRO Low Profile Air Strippers, contact your local Air-Met office.
- Patented multi-stage counter flow aeration provides up to 99.99% removal efficiency.
- Features vacuum-induced draft design that is more efficient than forced draft and eliminates fluid leakage between trays.
- Low profile modular design requires less floor and head space.
- Light weight modular polyethylene trays allow the addition or subtraction of trays to meet engineered treatment requirements.
- Stainless steel bubble plate design resists fouling.
- Highly effective on BTEX, MTBE, and Radon.
- Very easy to install and maintain.
- Remote monitoring and troubleshooting capability with the optional Geotech ECM.
- Available in 2 models:
- LO-PRO Model II
- LO-PRO Model III
LO-PRO Model II | LO-PRO Model III | |
---|---|---|
Applications | For use in non-classified and Class 1, Div. 2 locations |
High flow-rate for use in non-classified and Class 1, Div. 2 locations |
Dimensions | 5 tray unit: 66"L x 27"W x 75"H Each additional tray adds 10" to height |
3 tray unit: 91"L x 60"W x 70"H Each additional tray adds 13" to height |
Maximum No. of Trays | 8 | 5 |
Material | Linear Low Density Polyethylene Housing Stainless steel bubble plates |
Light Weight Polyethylene Housing Stainless steel bubble plates |
Water Flow | 1-20 gpm (4-76 l / min) | 1-60 gpm (4-227 l / min) |
Air Flow | Up to 250 CFM (7.1 CMM) | Up to 1100 CFM (31 CMM) |
Blower HP | 1-5 HP regenerative blower (TEFC: for use in Class 1, Div. 2 locations) |
10-15 HP centrifugal blower (TEFC: for use in Class 1, Div. 2 locations) |
Blower Voltage | 208-230/460V, 50 Hz or 60 Hz, 3 phase Single phase available |
208-230/460V, 50 Hz or 60 Hz, 3 phase |
Options | High pressure switch assembly, low pressure switch assembly, Geotech ECM controls and telemetry, motor starter package, sump water level sensor, additional trays, CFM gauge and valve assembly, transfer pumps. Explosion-proof blower. |
High pressure switch assembly, low pressure switch assembly, Geotech ECM controls and telemetry, motor starter package, sump water level sensor, additional trays, CFM gauge and valve assembly, transfer pumps. Explosion-proof blower. |
- Groundwater monitoring