HAZ-DUST 7204 Particulate Monitor

Personal real-time aerosol monitor, capable of measuring a wide variety of harmful particles and aerosols.  

SKU
HD7204

HAZ-DUST 7204 Particulate Monitor Overview

The SKC HAZ-DUST 7204, superseding the SKC SM-4000 Personal Silica Monitor, provides comprehensive, personal, real-time aerosol compliance monitoring for a wide range of harmful airborne particles.

The SKC HD-7204 is intended to allow Occupational Hygienists and safety professionals to immediately identify areas and tasks which carry a high risk of exposure to lung damaging particles and aerosols. When used as part of a routine air-monitoring program, the HD-7204 Particulate Monitor reduces the number of filter gravimetric tests and laboratory analysis required by returning accurate particulate concentrations in real-time. Immediate results reduce testing costs and ensure that workers can be alerted straight away if they are in danger so that corrective action can be taken.

The SKC HD-7204 aims to make particulate monitoring simple and accessible without sacrificing comprehensiveness or accuracy. The instrument eliminates the need to use both an FRM filter cassette and a real-time reading instrument. By offering a flow compensated pump, compatibility with all pre-weighed filter cassettes and with real-time measurements, the HD-7204 can be used in a wide variety of industries including those at risk of silica exposure, pharmaceuticals and construction dust.

A comprehensive personal particulate monitor, the HD-7204 Monitor protects workers through the breathing zone mounted sensor which is located next to either a 25 or 37mm filter cassette and the interchangeable sampling inlets for respirable, inhalable and thoracic particulate size fractions.

The graphical touch-screen display informs the wearer of real-time particulate concentration through time vs concentration graphs and an early warning alarm system when exposure thresholds are at risk of being exceeded.

Protect workers and ensure compliance with the SKC HAZ-DUST 7204 for real time, comprehensive personal aerosol and particulate monitoring.

For more information on the HAZ-DUST 7204 Particulate Monitor, contact your local Air-Met Scientific office.

HAZ-DUST 7204 Particulate Monitor Features

  • Flow compensated pump
  • Can accept any 37mm or 25mm pre-weighed and preloaded filter cassette
  • Tested and validated selective size respirable & Inhalable sampling inlets
  • Miniature sensor in breathing zone
  • Ability to create on screen aerosol profiles and to name data sets
  • Real-time rolling graphical display of airborne particulate concentration including comprehensive time vs concentration graphs
  • Large colour touch screen
  • Optional wireless connectivity
  • Impactors for PM10, PM5.0, PM4.0, PM2.5
  • Easy to clean optical sensor
  • Infield calibration verification
  • Early warning audible alarm signal of approaching threshold limits
  • Multiple language options

HAZ-DUST 7204 Particulate Monitor Specifications

Sensors Sensor Type: 90° light scattering 880nm
Calibration: Calibrated against Gravimetric reference NIST traceable- SAE fine test dust ISO12103-1 A2 Fine Test Dust.
Accuracy: +/- 10% to filter gravimetric SAE fine test dust
Precision: +/- 0.002 mg/m3 or 2 µg/m3
Sensing Range: 0.001-500 mg/m 3 or 1-500,000 µg/m3
PM Size Range: 0.1 to 100um
Minimum Resolution: 1 ug/m3 (0.001 mg/m3 )
Zero Stability: +/- 0.001 mg/m3 (give µg/m3 equivalent also) over 24 hours using 10 second log rate.
Humidity: 95% non-condensing
Display 3.5”, 24-bit True color, Resistive Color Touch, with Auto Dimming
Real-Time Data Display Time: Hours, min., sec., 12hour & 24 hour
Date: MM/DD/YYYY, YY/MM/DD, DD/MM/YY Data Display: Concentrations (mg/m3 , µg/m3), Sampling Size Fraction of PM (OSHA TWA, AVG., MAX., MIN.), Start time, stop time, elapsed run time, Log rate, Flow, Real-Time Rolling Graphs (10 sec and 1 second), Personalized Named Data Sets, Unique Aerosol Profiles, Language Options, Battery Life Pump Faults, Flow Rate, Infield Calibration Test, History of Data Sets
Sampling Flow Rate Sampling Flow Rate: 1-5 Lpm
The pump is capable to maintain flow within ±5% as follows: 1.0 Lpm up to 70 Inch H2O; 2.5 Lpm up to 55 Inch H2O, and 5.0 Lpm up to 20 inch H2O.
Filter Cassette 37mm preloaded and weighted filter cassette
37mm 1um jeweled cassette for diesel particulates
25mm Preloaded cassette
Attachable Inlets
Respirable Inlet GS-3 Cyclone: 2.75 LPM for 4µm cut point (OSHA silica rule) Meets ISO 7708/CEN criteria

GS-1 Cyclone: 2.0LPM for 4µm cut point (OSHA silica rule) 3 LPM for 3.5 cut point (MSHA silica standard) 1.7 or 2.0 LPM with DPM cassette (MSHA DPM sampling) Meets ISO 7708/CEN criteria
Inhalable Inlet IOM sampler: 2.0 LPM
Meets ISO 7708/CEN criteria
Thoracic Inlet Thoracic Sampling Inlet: 2.0LPM
Impactors PM10, PM5.0, PM4.0, PM2.5
Other Specifications
Alarm Output Audible & Visual
Audible: 90db at 3ft
Ceiling and S.T.E.L Alarms, Pump Fail, and Low Battery
Recording Time 1 second to 15 days
Sampling Rate: 1 sec., 4 sec., 10 sec., and 60 sec
Data Storage 43,200 data points
Memory & Time Storage >5 years
Digital Output Micro USB 6.00’ (1.83m), A Male to Micro B Male, 28SWG, Shielded
Power Supply Wall Mount, Multi Bald Included, Voltage Input 100~240
VAC, Voltage Output 12V, Current Output 2A, CE, UL,CB, cUL, PSE, RCM
Battery Lithium Ion pack, 7.4 Volt 3350 mAh, 24.79 watts
Operating Time 22+ hours Running at 2.0LPM with IOM and no filter
Operating & Storing Conditions Operating Temperature: 0 to 50°C
Storage Temperature: -20 to 70°C
Operational Humidity: 0-95% Non-Condensing
DUSTCOMM Pro Software Windows™ driven Windows 10 or greater
Maintenance Zero Calibration: Before each use
In Field Calibration Verification: Before each use
Flow Calibration: Before each use. Will automatically change when switching PM selective size.
Sensor Cleaning: By user when needed/ or during annual calibration
Factory Calibration: Annually or when instrument fails infield calibration verification.
Weight and Dimensions Dimensions (Case): 3.5” x 2.25” x 4.75”
Sensor Dimensions: 1.75” x 1.5”
Weight Instrument: 1.14lbs
Weight Sensor: 0.6lbs
Display dimensions: 3.5”
PM Sensor Sensor Type: 90° light scattering 88nm Calibrated against Gravimteric reference NIST traceable-SAE fine test dust ISO12103-1 A2 Fine Test Dust.
Tripod Mounting Optional Accessory

HAZ-DUST 7204 Particulate Monitor Applications

  • Particulate and aerosol monitoring of:
    • Silica
    • Diesel
    • Coal
    • Lead
    • Concrete/cement
    • Grinding dusts
    • Wood/paper
    • Chromate
    • Cadmium
    • Bush fire smoke
    • Tobacco smoke
    • Fumes
  • Construction dust
  • Soil remediations
  • Agriculture
  • Pharmaceutical manufacturing

HAZ-DUST 7204 Particulate Monitor Videos