Related Products
GA5000 Portable Landfill and Contaminated Land Gas Analyser
The GA5000 is a landfill and contaminated land portable gas analyser capable of measuring CH4, CO2, O2, H2S and CO.
SKU
GA5000
The GA5000 is a landfill and contaminated land portable gas analyser capable of measuring CH4, CO2, O2, H2S and CO. It is easy to use and calibrate, benefiting from Geotech's market leading reliability and helping you to standardise monitoring routines, whilst supporting environmental legislation compliance. The Geotech GA5000 portable gas analyser is perfect for landfill gas monitoring, waste to energy and site investigation applications.
Additional purchase options for the GA5000 portable landfill gas analyser include borehole gas flow, flow logging for improved borehole analysis, GPS/field navigator, an ATEX certified anemometer and more.
The GA5000 is currently available at Air-Met Scientific for both sales and rental.
For more information on the GA5000 Portable Landfill and Contaminated Land Gas Analyser, contact your local Air-Met office.
- Measures % CH4, CO2 and O2
- CH4 and CO2 accuracy +/-0.5% after calibration
- Measures barometric pressure and relative pressure
-
Memory: 2,000 IDs* and 4,000 readings (* with GAM software)
- Peak and previous readings shown
- Modular and upgradeable
- On board context-sensitive help
- Choice of user settings
- ATEX, IECEx, MCERTS, CSA and UKAS calibration (ISO17025) certified
- Additional Gas Analyser Manager software for data download available
- Optional accessories including ATEX certified anemometer
- Choices of borehole gas flow measurement; GPS / field navigator
- Optional additional gases (H2S up to 10000ppm and H2 compensate)
Technical Specifications | |
---|---|
Gases Measured | CH4, CO2, O2, H2S and CO (For more details about gases measured, please refer to the specification sheet) |
Power Supply | |
Battery Type | Rechargeable nickel metal hydride battery pack (not user replaceable) |
Battery Life | Typical use 8 hours from fully charged |
Battery Charger | Seperate intelligent battery charger powered from mains supply (100-240V) |
Charge Time | Approximately 4 hours from complete discharge |
Pump | |
Flow | 550 ml / min typically |
Flow Fail Point | -200 mbar vacuum - user settable |
Maximum Vacuum Restart | -375 mbar approx with flow rate of approx 80ml/min |
Facilities |
|
Temperature Measurement | -10°C to +75°C with optional probe |
Temperature Accuracy | ±0.5°C with optional probe |
Flow From Borehole | 0-20 l/hr internal measurement (optional) |
Flow From Borehole Accuracy | ±0.3 l/hr |
Alarm | User selectable alarm levels |
Communications | Via USB lead or wireless Bluetooth** |
Relative Pressure Measurement | ±500 mbar |
Relative Pressure Accuracy | ±4 mbar typically (should be zeroed before reading) to ±15 mbar max |
Barometric Pressure Measurement | 500 to 1500 mbar, ±5 mbar accuracy |
GPS Sensor | Location and positioning (optional) |
Available Memory | 2,000 IDs, 4000 readings** |
Environmental Conditions
|
|
Operating Temperature Range | -10°C to +50°C |
Atmospheric Pressure Range | 700 to 12 mbar |
Relative Humidity | 0-95% non condensing |
Case Seal | IP65 |
Physical | |
Weight | 1.6kg |
Size | L 220mm, W 155mm, D 60mm |
Display | Ultra-clear high resolution 4.3” full colour TFT |
Gas Sample Filters | External user changeable 2.0μm ptfe water traps |
Certification Rating | |
ATEX Marking | II 2G Ex ib IIA T1 Gb (Ta = -10°C to +50°C) |
MCERTS | MC130238 |
ISO17025 | Calibration to UKAS certificate number 4533 |
CSA | Ex ib IIA T1 (Ta= -10°C to +50°C) (Canada), AEx ib IIA T1 (Ta= -10°C to +50°C) (USA) |
** Gas Analyser Manager software required.
- Landfill gas monitoring
- Waste to energy
- Site investigation
- Landfill perimeter monitoring
- Landfill gas field management
- Gas flaring