FalcoTAC Fixed VOC Detector

Fixed VOC Detector designed specifically for continuous detection of Total Aromatic Compounds especially in extreme weather and condensing atmospheres.

SKU
FALCOTAC

Ion Science's FalcoTAC Fixed PID has been designed to accurately and reliably provide continuous detection of highly toxic aromatic compounds (TACs) such as benzene, toluene, xylene isomers.

Designed for plant-wide safety and the on-going protection of workers in the global petrochemical and oil and gas applications,The FalcoTAC detector gives you cutting-edge performance; reliability, accuracy and results you can trust so you can be sure workforce and plant receive on-going maximum protection. With its humidity resistance and anti-contamination design drift is minimised and run-time extended, saving both time and cost to your business.

Offering the ultimate in safety, FalcoTAC eliminates false readings found with other competing PID technology. Its multi-coloured LED status display can be seen from a distance of 20m in sunlight ensuring you are clearly alerted to hazards present.

FalcoTAC has an externally located Intrinsically Safe sensor for quick and easy servicing without the need for a hot work permit. Dual certification allows the Ion Science FalcoTAC to be serviced and calibrated in a hazardous environment without having to remove power.

Simple to operate the Ion Science FalcoTAC fixed VOC detector has an intuitive user interface. It has five magnetic switches with LED confirmation, a high contrast OLED screen and graphical interface ensuring installation and servicing are both quick and easy.

RS485 (Modbus®), 4-20 mA and Relay outputs are standard for all models. The Relay outputs are configurable for either high and low alarms, fault conditions or test cycle synchronisation.

The Ion Science FalcoTAC Fixed VOC Detector offers the ultimate in flexibility and can be purchased in either a pumped or diffused variant. With a diffused model, servicing costs are kept to a minimum with no pump to maintain. The Ion Science FalcoTAC is available in 4 detection ranges.

For more information, contact your local Air-Met Scientific office.

ION Science FalcoTAC Fixed VOC Detector Features

Ultimate Performance

  • The only VOC detector specifically designed for extreme weather 
  • Ion Science Typhoon Technology stops condensation forming within the PID
  • Cutting-edge sensor performance minimises drift & downtime

Ultimate Flexibility

  • Available in pumped or diffused models 
    • Pumped unit ideal for difficult to access locations 
    • Diffused model reduces servicing costs 
  • Four detection ranges available 
  • Selectable response factor for varying VOC selection

Ultimate Safety

  • Eliminates false readings found with other PIDs 
  • Multi-coloured status display seen from 20 metres in sunlight 
  • Fitted with long-life lamp for one year of continuous use 
  • Intrinsically safe; meets ATEX, IECEx, North American and Canadian standards
Ion Science FalcoTAC Technical Specifications
Sensor Photoionisation
Detection ranges and sensitivity with 10.6eV lamp fitted
  • 10.0 ppm* 0.001 ppm 
  • 50.0 ppm*0.01 ppm 
  • 1000 ppm* 0.1 ppm 
  • 3000 ppm* 1 ppm 
Detection time (T90) 
  • Diffused models: <30 seconds**
  • Pumped models: variable 
User Interface
  • Display: OLED high contrast white on black: 128 (w) x 64 (h) pixels 
  • Screen size: 35 mm (w) x 17.5 mm (h)  
  • 5 magnetic switches with LED confirmation (up, down, left, right & enter). Magnetic actuator supplied.
Status Indicator Bright visible status indicator: red, amber green
Certification
  • II 2G Ex d ib IIC T4 Gb 
  • Class 1, Div 1 Groups ABCD T4 
  • ISO9001:2008
Environmental Specification
  • Without pump: -40°C to 60°C (-40°F to 140°F)
  • With pump: -20°C to 60°C (-4°F to 140°F) 
  • 0-100% RH and condensing humidity
Mechanical Interface
  • 2 x cable entry points with 3/4” NPT threads (left and right)
  • 2 x 3/4” NPT to M20 Stainless steel (supplied)
Dimensions
  • Without pump: 200 (h) x 190 (w) x 125 (d) mm
  • With pump: 290 (h) x 190 (w) x 125 (d) mm
Mounting Points 2 x M8
Input Power
  • Working voltage: 12 to 40 Vdc
  • Max. power: 7 watts
Outputs
  • 4 to 20 mA (active and passive) 
  • RS485 supports Modbus® protocol 
  • Relay x 2 SPST (60 Vdc 2A) – configurable

* All specifications quoted are at calibration point and under the same ambient conditions.
** When set to continuous measurement

ION Science FalcoTAC Fixed VOC Detector Applications

  • Manufacturing 
  • Processing 
  • Refineries & Petrochemical
  • Chemical 
  • Waster water treatment 
  • Pulp & paper 
  • Pharmaceutical 
  • Indoor Air Quality (IAQ)
  • Solvent recovery systems 
  • Industrial painting & coating
  • Fenceline monitoring 
  • Outdoor air quality 
  • Tankfarms 
  • Bunkering

ION Science FalcoTAC Fixed VOC Detector Support Material

FalcoTAC Fixed VOC Pumped Brochure

FalcoTAC Diffused Model Brochure

FalcoTAC Fixed VOC Manual