Introducing the NEW Tiger XT Detector Range from Ion Science
For Rapid and Accurate Detection of VOCs, Benzene and TACs
Since the release of the PhoCheck Tiger back in the 2000’s followed by the Tiger Select in 2011, Ion Science’s high performance photoionisation detectors (PIDs) have been trusted by industry professionals and used in a wide variety of industries, from construction sites to water governing bodies for the monitoring of VOCs, benzene and TACs.
Taking on customer feedback, the team at Ion Science have now released three new detectors in the NEW Tiger XT range which will be directly replacing the PhoCheck Tiger, Tiger Select and the Tiger LT. The new Tiger XT Series will be available in Australia from 22 November 2022 with is predecessors discontinued effective immediately.
The following products in the Ion Science Tiger range will be discontinued:
TIGERLT VOC Detector, standard & premium kit 10.6eV
TIGER Instruments & variants
TIGER 11.7eV Instruments & variants
TIGER Select Instrument & variants
TIGER Fire Investigation Kit & variants
The Tiger XT Gas Detector Series – Tiger XT, Tiger XTL and Tiger XTS
Three models will be released to replace the existing PhoCheck Tiger Range.
Ion Science’s primary detector is the Tiger XT VOC Gas Detector which will be directly replacing the PhoCheck Tiger VOC Meter. Featuring Ion Science’s patented Fence Electrode Technology, the Tiger XT has been independently verified as the most advanced handheld VOC detector on the market designed for the rapid and accurate detection of VOCs down to 1 part per billion (ppb) up to 20,000 parts per million (ppm).
The Tiger XTL will be replacing the Tiger LT, its low-cost VOC detector option with reliable market leading accuracy. Although cost-efficient, the Tiger XTL still features Ion Science’s patented PID sensor technology with resistance, anti-contamination design, rugged design and more.
The Tiger XTL is IECEx certified and is ideal for field work including environmental monitoring, soil contamination VOC monitoring in landfills and more.
The third model in the Tiger XT Series is the Tiger XT Select Portable Benzene Gas Detector. Utilising the high output of the Ion Science 10. eV lamp, the Tiger XTS supersedes the Tiger Select Gas Detector and is capable of detecting benzene, toluene and acetone.
Tiger XT 10.6 eV
Tiger XTL
VOC Detection Range
1 ppb - 20,000 ppm
0.1 – 5,000 ppm
Min. Resolution
1 ppb
0.1 ppm
Lamp Options
10.0 eV, 10.6 eV, 11.7 eV
10.6 eV Krypton PID lamp (standard)
Solutions to High Humidity
Patended Fence Electrode
Instrument Weight
870g
Tiger XTS Select 10.0 eV Benzene Detector
Benzene Detection Range
0.01 ppm - 200 ppm
Benzene Min. Resolution
10 ppb
Lamp Warranty
1 year
Internal Gas Table
> 700
Revolutionary Handheld VOC Meters with Improved Robust Designs
The new Tiger XT Series has been updated to feature more robust design, enclosure, and user experience. Improvements include:
Improved front window LCD design, overmoulded with TPE to reduce potential for display damage
Thermo plastic elastomer outer moulding making the Tiger XT Series more robust in the field
Brass inserts for screw cavity – prevents cross threading and damage to moulding
USB connecter ports are now protected from ingress
Tiger XT features a push to release button for quick, easy and secure battery connection.
For current owners of the Tiger instrument range, all Tiger instruments will continue to be supported with warranty replacement parts for the duration of the warranty period, subject to parts availability.