BioStage Single-Stage Viable Bioaerosol Impactor
Meets NIOSH and ACGIH Recommendations For Sampling Indoor and Outdoor Air For Viable Microorganisms.
SKU
BIOSTAGE
The BioStage single-stage cascade impactor operates on the principle of inertial impaction and meets NIOSH and ACGIH recommendations for sampling indoor and outdoor air for viable microorganisms, including bacteria, and fungi.
Made of precision-tooled aluminium, the sampler contains a jet classification stage and base plate precision-threaded together for a positive seal and an inlet cone. The impactor stage contains precision-drilled holes. A sample pump draws air through the sampler where multiple jets of air direct airborne particles toward the surface of the agar collection medium.
Two models of the BioStage Impactor are available to accommodate two different flow rates.
For more information on the BioStage Single-stage Bioaerosol Impactor, contact your local Air-Met office.
- Easy to use
- Proven principle of operation
- Meet ACGIH recommendations for bioaerosol sampling
- Meet NIOSH Method 0800 and 0801 requirements
- Performance equivalent to Andersen N-6 and Aerotech 6
- Corrosion-resistant aluminium
- Autoclavable
- Collected organisms remain intact and viable
- Easy setup and calibration
- SureLock positive seal ensures sample integrity
Flow Rate |
Standard BioStage: 28.3 L/min
BioStage 200: 14.15 L/min
|
Material |
Inlet cone and base plate: Precision-tooled autoclavable aluminum
O-rings: Duro 50, BUNA-N (not autoclavable )
|
Jet Classification Stage |
Standard: 400 holes (0.25-mm hole diameter)
BioStage 200: 200 holes (0.25-mm hole diameter)
|
Sample Media | 90 to 100-mm agar plates* |
Suggested Media |
For bacteria:
Tryptic Soy Agar (TSA)
Blood Agar Plates (BAP)
For fungi:
Potato Dextrose Agar (PDA)
Malt Extract Agar (MEA)
Dichloran Glycerol 18 Agar (DG-18)
Corn Meal Agar (CMA)
|
Analysis | Colony culture |
Tubing | 1/4-inch ID |
Standard BioStage | BioStage 200 | |
---|---|---|
Jet Classification Stage |
400 holes (0.25-mm dia.)
|
200 holes (0.25-mm dia.)
|
Sample Rate | 28.3 L/min | 14.15 L/min |
Median Cut Point (D50) | 0.6 µm | 0.6 µm |
Sample Media | 90 to 100-mm agar plates | 90 to 100-mm agar plates |
Analysis | Colony culture | Colony culture |
Tubing | 1/4-inch ID | 1/4-inch ID |
- Indoor Air Quality (IAQ) studies
- Filter and cleanroom efficiency studies
- Pharmaceutical production
- Brewery fermentation
- Animal care laboratories
- Food processing areas
- Sewage treatment plants
- Hospital environments
- Cosmetic manufacturing
- Grain processing and transportation
- Bio-risk response