AirMetER-AX Air Quality Monitoring Station
Near Real-Time Monitoring Station for Particulate Matter, Gas, Environmental Conditions and Noise.
AirMetER-AX Air Quality Monitoring Station Overview
Compact and easy to install, the AirMetER-AX is a certified Australian Made air quality monitoring station that is locally designed and supported by Air-Met Scientific’s inhouse engineering team. The modular design allows the unit to support:
- 1-8 gas sensors
- Simultaneous measurements for PM2.5 and PM10
- Optional PM1, PM4.25 and TSP
- Noise and vibration monitoring
Housed in a weather resistant enclosure, the AirMetER-AX is ideal for continuous outdoor monitoring with a datalogging capacity at a minimum of 365 days at one-minute intervals. Additionally, the built-in log and forward capability locally stores data in the event of a network disruption to prevent data loss.
Integrating seamlessly with Air-Met Scientific’s web-based portal LiveSense for remote data access, this secure data portal enables Air-MetER AX owners to access monitoring logs, set customisable alerts, manage monitoring reports and more. LiveSense is accessible on both desktop PC and mobile smart devices.
For more information about the AirMetER-AX Monitoring Station, contact your local Air-Met Scientific office today.
Already an AirMetER Series customer?
AirMetER-AX Air Quality Monitoring Station Features
- Simultaneous PM2.5 and PM10 measurement with heated inlet
- Optional support for PM1, PM4.25 and TSP
- Simultaneously monitor 1-8 different gases. Available gases – CO, CO2, VOC, SO2, H2S, O2, O3, NO and NO2
- Weather monitoring
- Noise and vibration monitoring
- Humidity correction
- Low maintenance
- Over the air (OTA) K-factor correction(requires gravimetric sample data)
- Local service and support with Air-Met Scientific
- Australian Made accredited
AirMetER-AX Air Quality Monitoring Station Specifications
Refer to the datasheet for the most up to date specs
GENERAL | |||
Power Requirement | 12VDC | ||
Rated Power | 43W | ||
Operating Temperature | 0 to 50ºC | ||
Operating Humidity | 0 to 95% non-condensing | ||
Operating Pressure | 860 to 1100 hPa | ||
Particulate Sensor Operating Life | 2 years (when operating below 40ºC) | ||
Datalogging (optional) | 3 years of logs onboard with unique file name creation every 24 hours | ||
PARTICULATE MEASUREMENTS | |||
AirMetER-AXII (PM2.5 &PM 10) |
AirMetER-AXIV (PM1, PM2.5, PM4.25, PM10 and TSP) |
||
Range | 0−999.9µg/m3 | 0−30,000μg/m3 | |
Resolution | 0.1μg/m3 | 1μg/m3 | |
Relative Error | Max of ±15% and ±10μg/m3 | PM1/PM2.5/PM4.25 ±10% of reading PM10 ±15% of reading TSP ±20% of reading ^Up to 1000μg/m3 |
GAS MEASUREMENTS (specifications are based on 20°C and 800-1200 hPa conditions) |
|||
Type | Range | Resolution | Min. Repeatable Detectable Level |
CO (low range) | 0-10ppm | 1ppb | 20ppb |
CO (high range) | 0-300ppm | 1ppm | N/A |
CO2 | 0-5000ppm | 1ppm | 15ppm |
VOC (low range) | 0-20ppm | 1ppb | 15ppb |
VOC (high range) | 0-200ppm | 0.1ppm | N/A |
SO2 | 0-10ppm | 1ppb | 20ppb |
H2S (low range) | 0-2ppm | 1ppb | 20ppb |
H2S (high range) | 0-100ppm | 0.1ppm | N/A |
NO2 (low range) | 0-1ppm | 1ppb | 20ppb |
NO2 (high range) | 0-20ppm | 0.1ppm | N/A |
O3 | 0-1ppm | 1ppb | 20ppb |
O2 | 0-25%VOL | 0.1% VOL | N/A |
NO | 0-5ppm | 1ppb | 20ppb |
Additional gases are available upon request. Contact your local Air-Met Scientific for more information. |
WEATHER SENSOR (Integrated climate sensor for weather monitoring) | |
Wind Speed | 0 to 60.0 m/s |
Wind Direction | 0° to 360.0° |
Air Temperature | -40.0 to +60.0°C |
Relative Humidity | 0 to 100.0% |
Barometric Air Pressure | 800.0 to 1060.0 hPa |
Precipitation | 0.00 to 100.00 mm/h |
NOISE (Integrated noise monitor using TA120) | |
Range | 35.0 to 120.0 dB |
Resolution | 0.1 dB |
Accuracy | According to IEC 61672-1 Class 1 |
ENCLOSURE | ||
Material | Polycarbonate | |
Dimensions (mm) | 500mm H x 400mm W x 210mm D | |
Instrument Weight | 15kg | |
Mounting Options | Pole-mount kit supplied (recommended installation method) Wall-mount : ~70mm offset required for dust inlet clearance |
|
COMMUNICATION | ||
PLC or SCADA Integration | Serial RS485, Modbus TCP/IP (AX-IV only) | |
FTP Upload | Cellular, Ethernet or Wi-Fi |
SPARE PART & ACCESSORIES | ||
TF-TRI-AL | 1.2m Tripod | |
AMS/250S/120B/15M/9C | 120 Ah Lithium Solar Battery Kit | |
AMS-LPF-60-12 | Power Supply (100 - 240VAC Input) | |
9933-05-CQ | Dust Filter for AX-II Module | |
SF-OPC6303-15-QN | Dust Filter for AX-IV Module | |
17576-K-EACH | Gas Filter | |
AMS-ALARM | Built in audible and visual alarm | |
AMS-HMI | Integrated local display |
For all additional sensors, please contact Air-Met Scientific.
AirMetER-AX Air Quality Monitoring Station Applications
- Industrial perimeter monitoring
- Urban pollution monitoring
- Park and outdoor air pollution monitoring
- Public nuisance monitoring
- Air pollution monitoring in construction sites
AirMetER-AX Air Quality Monitoring Station Support
LiveSense Cloud Portal User Guide
Quick Guides
AirMetER Series Decommissioning Guide
AirMetER-AX Installation Guide
AirMetER-AX Particulate Sensor Module Removal & Replacement Guide