Airchek XR5000 Direct Flow Compensated Personal Sampling Pump

Extended Flow Range Suitable for Low Flow Gas/Vapour or High Flow Particulate Sampling.

SKU
XR5000

Discover the perfect combination of features and power in this compact, lightweight pump that gets the job done. The AirChek® XR5000 Personal Sample Pump with Li-Ion battery provides powerful flows for particulate sampling, low flows for gas and vapor sampling, and the long run-times for low-concentration sampling.

For more information on the Airchek XR5000, contact your local Air-Met office. 

  • Extended flow range: 5 to 5000 ml/min
  • Suitable for low flow gas/vapor or high flow particulate sampling
  • Optional low flow tube holder (low flow adapter kit Cat. No. 210-500) used with CPC allows up to four tube samples to be taken simultaneously, each at different flow rates if desired. 
  • Extended back pressure capabilities
  • Up to 50 inches of water at 2 L/min
  • Enhanced battery power for extended run times*
    XR Model2 L/min5 L/min
    High Power Li-Ion 40 hours 22 hours
    Standard Li-Ion 20 hours 11 hours
    * Results of run time tests using 37-mm, 0.8-µm MCE filters with new pumps and batteries. Pump and battery performance may vary.
  • For extended run times, the pump may be operated while attached to the charger
  • 2 interchangeable battery options
    • High-power Li-Ion for extended runs
    • Standard Li-Ion for lighter weight
  • Patented** highly accurate isothermal flow control system\
    • Compensates with ± 5% accuracy
  • UL Listed for intrinsic safety
  • Automatic flow correction for changes in temperature provides accurate air volumes
  • Extremely simple operation
    • Easy-to-use three-button keypad
    • Continuous run with the push of a button
    • Bright blue pump status LED
    • Easy-to-read LCD displays elapsed time and accumulated run time
  • Set-and-go timer
    • Timed and delayed runs up to 9999 minutes
  • Sample Integrity
    • Lockable keypad
    • Automatic flow fault
    • Auto-restart attempted after 15 seconds in flow fault
    • Flow correction for changes in temperature
    • Accumulated run time display
    • Battery status indicator 
  • Standard model weighs only 16 ounces (454 grams)
  • RoHS compliant
  • Components meet Euro directive for reduction of hazardous substances (including lead) to support green initiatives
  • ** U.S. Patent No. 5,892,160
 
Flow Range 1000 to 5000 ml/min  (5 to 500 ml/min requires optional low flow adapter kit)
Compensation Range
5000 ml/min at 10 inches water back pressure
4000 ml/min at 20 inches water back pressure
2000 ml/min at 50 inches water back pressure
Typical Back Pressure of Sampling Media (inches water)
Flow Rate (L/min)1.01.52.02.53.03.54.05.0
Filter/Pore Size (µm)
               
25-mm MCE/0.8 6 9 12 15 18 21 25 31
25-mm MCE/0.45 14 22 28 35 40 44 50 63
37-mm MCE/0.8 2 3 4 5 6 7 9 11
37-mm PVC/5.0 1 1 2 2 2.5 3 3 4
37-mm polycarbonate/0.45 4 6 8 10 12 15 17 21
25-mm MCE/0.45 microvacuum 21 31 40 48 59 69 79 100
37-mm PTFE/1.0 1.5 2.5 4 5.5 7 8 9.5 12
Compare the information in this table to pump compensation range to determine appropriate applications.
Flow Compensation System
Patented isothermal closed loop flow sensor (U.S. Patent No. 5,892,160)
Tubing Requires 1/4-inch ID tubing
Accuracies
Timing: 1 min/mo at 25°C 
Flow Rate: ± 5% of set-point after calibration to desired flow
Battery Charge Level Indicator Icon displays on LCD at full, mid, low charge, imminent low battery fault, and low battery fault.
Temperature Range
Operating: 32° to 113°F (0° to 45°C) 
Charging: 32° to 113°F (0° to 45°C) 
Storage: -4° to 95°F (-20° to 35°C)
Typical Run Times
XR5000 Model2 L/min5 L/min
High Power Li-Ion 40 hours 22 hours
Standard Li-Ion 20 hours 11 hours
Timer Display Range
1 to 9999 minutes (6.8 days). If run time exceeds 6.8 days, timer display rolls over.
Flow Fault
If pump is unable to compensate for > 15 seconds due to excessive back pressure, the pump stops and holds run time display. Auto-restart is attempted every 15 seconds up to 5 times.
Low Battery Fault 15 sec to sleep
Auto-off 5 min of inactivity
Battery Pack (model dependent)
High-power Li-Ion (4 cell), rechargeable, 7.4 V, 4.4 Ah, 32.6 Wh capacity
Standard Li-Ion (2 cell), rechargeable, 7.4 V, 2.2 Ah, 16.3 Wh capacity
Battery Recharge Time (with SKC-approved charger) 
Standard Li-Ion (2 cell): approximately 4 hrs
High-power Li-Ion (4 cell): approximately 8 hrs
Size
High-power Li-Ion and alkaline models: 5.5 x 3 x 2.3 in (14 x 7.6 x 5.8 cm) 
Standard Li-Ion model: 4.3 x 3 x 2.3 in (10.9 x 7.6 x 5.8 cm)
Weight
High-power Li-Ion model: 21 oz (0.6 kg) 
Standard Li-Ion model: 16 oz (0.45 kg)
Case Anti-static plastic
RFI/EMI Shielding CE marked for RFI/EMI protection
Approvals
  • UL Listed for Intrinsic Safety (These models must be used with battery pack Cat. No. P85004 or P85002 to maintain the UL intrinsic safety listing.)
  • RoHS compliant

 

  • Low flow gas/vapour sampling
  • High flow particulate sampling