Discover the perfect combination of features and power in this compact, lightweight pump that gets the job done. The AirChek® XR5000 Personal Sample Pump with Li-Ion battery provides powerful flows for particulate sampling, low flows for gas and vapor sampling, and the long run-times for low-concentration sampling.
For more information on the Airchek XR5000, contact your local Air-Met office.
- Extended flow range: 5 to 5000 ml/min
- Suitable for low flow gas/vapor or high flow particulate sampling
- Optional low flow tube holder (low flow adapter kit Cat. No. 210-500) used with CPC allows up to four tube samples to be taken simultaneously, each at different flow rates if desired.
- Extended back pressure capabilities
- Up to 50 inches of water at 2 L/min
- Enhanced battery power for extended run times*
XR Model 2 L/min 5 L/min High Power Li-Ion 40 hours 22 hours Standard Li-Ion 20 hours 11 hours * Results of run time tests using 37-mm, 0.8-µm MCE filters with new pumps and batteries. Pump and battery performance may vary. -
For extended run times, the pump may be operated while attached to the charger
-
2 interchangeable battery options
-
High-power Li-Ion for extended runs
-
Standard Li-Ion for lighter weight
-
-
Patented** highly accurate isothermal flow control system\
-
Compensates with ± 5% accuracy
-
-
UL Listed for intrinsic safety
-
Automatic flow correction for changes in temperature provides accurate air volumes
- Extremely simple operation
- Easy-to-use three-button keypad
- Continuous run with the push of a button
- Bright blue pump status LED
- Easy-to-read LCD displays elapsed time and accumulated run time
- Set-and-go timer
- Timed and delayed runs up to 9999 minutes
- Sample Integrity
- Lockable keypad
- Automatic flow fault
- Auto-restart attempted after 15 seconds in flow fault
- Flow correction for changes in temperature
- Accumulated run time display
- Battery status indicator
- Standard model weighs only 16 ounces (454 grams)
- RoHS compliant
- Components meet Euro directive for reduction of hazardous substances (including lead) to support green initiatives
- ** U.S. Patent No. 5,892,160
Flow Range | 1000 to 5000 ml/min (5 to 500 ml/min requires optional low flow adapter kit) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Compensation Range |
5000 ml/min at 10 inches water back pressure
4000 ml/min at 20 inches water back pressure
2000 ml/min at 50 inches water back pressure
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Typical Back Pressure of Sampling Media (inches water) |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Compensation System
|
Patented isothermal closed loop flow sensor (U.S. Patent No. 5,892,160)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Tubing | Requires 1/4-inch ID tubing | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Accuracies |
Timing: 1 min/mo at 25°C
Flow Rate: ± 5% of set-point after calibration to desired flow
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Battery Charge Level Indicator | Icon displays on LCD at full, mid, low charge, imminent low battery fault, and low battery fault. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature Range |
Operating: 32° to 113°F (0° to 45°C)
Charging: 32° to 113°F (0° to 45°C)
Storage: -4° to 95°F (-20° to 35°C)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Typical Run Times |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Timer Display Range |
1 to 9999 minutes (6.8 days). If run time exceeds 6.8 days, timer display rolls over.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Fault |
If pump is unable to compensate for > 15 seconds due to excessive back pressure, the pump stops and holds run time display. Auto-restart is attempted every 15 seconds up to 5 times.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Low Battery Fault | 15 sec to sleep | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Auto-off | 5 min of inactivity | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Battery Pack (model dependent) |
High-power Li-Ion (4 cell), rechargeable, 7.4 V, 4.4 Ah, 32.6 Wh capacity
Standard Li-Ion (2 cell), rechargeable, 7.4 V, 2.2 Ah, 16.3 Wh capacity
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Battery Recharge Time (with SKC-approved charger) |
Standard Li-Ion (2 cell): approximately 4 hrs
High-power Li-Ion (4 cell): approximately 8 hrs
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Size |
High-power Li-Ion and alkaline models: 5.5 x 3 x 2.3 in (14 x 7.6 x 5.8 cm)
Standard Li-Ion model: 4.3 x 3 x 2.3 in (10.9 x 7.6 x 5.8 cm)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight |
High-power Li-Ion model: 21 oz (0.6 kg)
Standard Li-Ion model: 16 oz (0.45 kg)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Case | Anti-static plastic | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RFI/EMI Shielding | CE marked for RFI/EMI protection | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Approvals |
|
- Low flow gas/vapour sampling